加入收藏 在線留言 聯系我們
          關注微信
          手機掃一掃 立刻聯系商家
          全國服務熱線19079192829
          公司新聞
          故障診斷和排除(三十三)C15發動機增壓器 噴油器 進排門 零部件
          發布時間: 2023-07-01 12:31 更新時間: 2024-11-01 17:00

          產品:     EXCAVATOR

          型號:     311B EXCAVATOR 2LS

          配置:   311B TRACK-TYPE EXCAVATORS 2LS00001-UP (MACHINE) POWERED BY 3064 ENGINE

          4506219430.jpg

          故障診斷和排除

          Air Conditioning and Heating R134a for All Caterpillar Machines

          Automatic Temperature Control System (ECM Controlled) Troubleshooting

          SCS - 7309-035-YC; 7610-035-ACD

          Automatic Temperature Control Troubleshooting Codes controlled by Machine ECM

          Use this procedure to troubleshoot the performance of the HVAC system for machines equipped with automatic temperature control.

          Connect Electronic Technician (ET) and check for diagnostics associated with the HVAC system. Refer to the Machine Troubleshooting Guide if any of the following codes are active. 

          Typical HVAC ET status parameters and values

          Symptom Troubleshooting

          Cab Temperature is Hig

          Probable Causes

          ?  Diagnostic Codes

          ?  Low Pressure Switch / High Pressure Switch

          ?  Low Refrigerant Charge

          ?  Water Valve Actuator

          ?  A/C Compressor

          Recommended Actions

          Diagnostic Codes

          Connect Cat ET to the service tool connector. Check for active diagnostic codes. Look for active codes that are related to the HVAC system in Illustration 1. Use the appropriate circuit test to     troubleshoot any active codes before continuing.

          Low Pressure Switch / High Pressure Switch

          Use Cat ET to monitor the "Air Conditioning Refrigerant Monitoring Circuit" status parameter. With a proper charge the status should be closed. If the status is open, heck the pressure switches and         circuit (refer to the pressure switch tests section in this book).

          Low Refrigerant Charge

          Refer to Air Conditioning Performance - Test

          我司主要提供: 

          柴油零部件,發電機組零部件

          總成、缸套組件、活塞組件、四配套、活塞、連桿、活塞銷、曲軸、大修包、渦輪增壓器 、中缸總成、氣缸蓋總成、氣門室蓋、進氣門、排氣門、進氣門座圈、排氣門座圈、門彈簧、氣門鎖片、進、排氣門導管、噴油嘴總成、噴油嘴、柴油泵總成、柱塞、出油閥、進氣支管、排氣支管、缸套、活塞環、連桿瓦、主軸瓦、機油泵總成、機油散熱器、機油散熱器邊蓋、冷卻水箱、上、下水管、風扇葉、正時齒輪室、蓋 、曲軸正時齒輪 隋輪齒、凸輪軸齒、油泵齒、水泵總成、加油馬達、熄火開關、蓄電瓶、軸螺栓、缸蓋螺栓、機油感應器、水溫報警器、聯軸器、高壓油管、接頭、進油管、卡子。

          Water Valve Actuator

          Test the water value actuator control by switching to heat mode. Use Cat ET and monitor the "Cab Air Heater Engine Coolant Actuator Duty Cycle" status parameter while rotating the temperature    dial. The parameter should go to 5% when the temperature dial is full CCW and 95% when the       temperature dial is full CW. If the Cab Air Heater Engine Coolant Actuator Duty Cycle" doesn't     move with the temperature dial, check the temperature dial (see the troubleshooting section 2661 in the machine troubleshooting guide). If the Cab Air Heater Engine Coolant Actuator Duty Cycle"    moves with the temperature dial, verify the water valve actuator circuit and that the actuator is        rotating.

          A/C Compressor

          Switch to AC mode and use Cat ET to monitor the "A/C Compressor" status parameter with the         engine running. If the compressor status does not turn to ON after 20 seconds, check the evaporation temperature circuit (refer to 2357 diagnostic code in the machine TSG) and the pressure switch          circuits (refer to the pressure switch tests section in this book). If the compressor status is ON and the compressor does not turn on, check for power at the compressor connection.

          Note: If the compressor status is on and there is power at the compressor clutch, then replace the

          compressor.

          Cab Temperature Low

          Probable Causes

           

          ?  Diagnostic Codes

          ?  Water Valve Actuator

          Recommended Actions

          Diagnostic Codes

          Connect Cat ET to the service tool connector. Check for active diagnostic codes. Look for active codes that are related to the HVAC system in Illustration 1. Use the appropriate circuit test to     troubleshoot any active codes before continuing.

          Water Valve Actuator

          Test the water value actuator control by switching to heat mode. Use Cat ET and monitor the "Cab Air Heater Engine Coolant Actuator Duty Cycle" status parameter while rotating the temperature 

          dial. The parameter should go to 5% when the temperature dial is full CCW and 95% when the       temperature dial is full CW. If the Cab Air Heater Engine Coolant Actuator Duty Cycle" doesn't     move with the temperature dial, check the temperature dial (see the troubleshooting section 2661 in the machine troubleshooting guide). If the Cab Air Heater Engine Coolant Actuator Duty Cycle"    moves with the temperature dial, verify the water valve actuator circuit and that the actuator is        rotating.

          No airflow from Evaporator Blower Motor

          No Auto Blower Control

          Perform this test with the key on. Use a 5P-7277 Voltage Tester or use a 9U-7330 Digital Multimeter and connect the negative probe to the pin 7 wire on the control panel using a 7X-1709 Multimeter      Probe or equivalent. Check the supply voltage first by connecting the positive probe to the pin 1 wire using a 7X-1708 Multimeter Probe or equivalent. If the system voltage is not measured do not            perform any of the other tests below until that is repaired. Select the blower switch to the low speed   and connect the positive probe to pin 5 using a 7X-1708 Multimeter Probe or equivalent and record   the voltage. For a properly working control panel the voltage should be the same as the system           voltage. Repeat for all speeds. Replace the panel if any of the voltages are not present during the test. If the panel passes the test then refer to the machine electrical schematic and check for voltage to the motor and resistor.

          Auto Blower Controls

          (1) 288-8557 Air Conditioner and Heater Control As - HVAC (Blower Speed)

           Perform this test with the key on. Connect ET and look for diagnostics relating to the control panel (2811-3, 2811-4). Use the following procedure to troubleshoot the diagnostics.

          Use a 5P-7277 Voltage Tester or use a 9U-7330 Digital Multimeter and connect the negative probe to the pin 6 wire on the control panel using a 7X-1709 Multimeter Probe wire assembly or equivalent     and connect the positive probe to the pin 4 wire. Rotate the dial and observe the voltage reading, the   voltage should vary between 2 to 4.5 V for a properly working panel.

          If the panel passes the test then refer to the machine troubleshooting guide and check for voltage to the motor and driver module if equipped.

          其他新聞

          聯系方式

          • 電  話:19079192829
          • 市場經理:鄧先生
          • 手  機:19079192829
          • 微  信:zzzx-3699